Airpax Circuit Breaker P/N: APL-11-4088-1 NSN: 5925-01-123-2045

Please fill out the form below for a price quote and availability on this item.

Circuit Breaker

NSN: 5925-01-123-2045  P/N: APL-11-4088-1  Model: SM-C-739863-1
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elem en (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto breaker assemblies. See also switch (as modified) ; and controller.

NSN Properties and Flags
NATO Stock Number
5925-01-123-2045
DEMIL
Yes - ITAR Controlled
Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Style
Multipole-multiple actuator type
Body Length
Between 2.480 inches and 2.500 inches
Body Width
1.500 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
Fragility Factor
Moderately rugged
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.475 inches
Pole Quantity
2
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 1000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One and two linked
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct all locations and 1.800 at 200 pct all locations
Inclosure Protection Type For Which Designed
Moisture resistant and salt spray proof and shock resistant and vibration resistant
Frequency In Hertz
50.0 all locations or 60.0 all locations
Unpackaged Unit Weight
7.400 ounces
Thread Series Designator
Unc
Terminal Type And Quantity
4 threaded stud