Circuit Breaker NSN: 5925-01-123-2045 P/N: APL-11-4088-1

Please fill out the form below for a price quote and availability on this item.

Circuit Breaker- A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Actuator Function: Trip-reset
Actuator Position Designation: At each pole
Arc Quenching Method: Magnetic blowout
Body Length: 2.480 inches minimum and 2.500 inches maximum
Body Style: Multipole-multiple actuator type
Body Width: 1.500 inches maximum
Boss Height: 0.150 inches nominal
Case Material: Plastic
Center To Center Distance Between Terminals Parallel To Length: 1.940 inches nominal
Center To Center Distance Between Terminals Parallel To Width: 0.750 inches nominal
Circuit Protection Type: Overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length: 2.050 inches minimum and 2.070 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width: 0.750 inches nominal
External Actuator Linkage Arrangement: One and two linked
Fragility Factor: Moderately rugged
Frequency In Hertz: 50.0 all locations or 60.0 all locations
Maximum Continuous Load Current Rating Per Pole: 20.0 amperes ac all locations and 20.0 amperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps: 1000.0 ac all locations and 1000.0 dc all locations
Mounting Facility Type And Quantity: 4 threaded hole
Mounting Surface To Terminal End Distance: 2.475 inches nominal
Nominal Thread Size: 0.138 inches
Operating Voltage Type And Rating Per Pole In Volts: 250.0 ac all locations and 50.0 dc all locations
Inclosure Protection Type For Which Designed: Moisture resistant and salt spray proof and shock resistant and vibration resistant
Internal Trip Release Configuration: Series trip all locations
Main Contact Tripping Mechanism Type: Trip free
Manual Actuator Type And Quantity: 2 toggle
Reset Method: Manual
Pole Quantity: 2
Special Handling Feature: Magnetic
Storage Type: General purpose warehouse
Terminal Type And Quantity: 4 threaded stud
Thread Pitch Diameters: +0.1177/+0.1214 inches
Thread Quantity Per Inch: 32
Thread Series Designator: Unc
Trip Delay Time In Seconds Per Rated Continuous Current: 0.180 minimum at 200 pct all locations and 1.800 maximum at 200 pct all locations
Trip Release Characteristic: Time delay all locations
Trip Release Method: Magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent: 115.0 all locations
Unpackaged Unit Weight: 7.400 ounces

This product is only available upon request. Contact us by e-mail or by filling out the form below for a quote.